Low Smoke Halogen Free (LSHF) XLPE insulated 1KV low voltage cable
what's LSFH Cable?
With the increased demand for safety in public areas and buildings, contractors are now being advised to install materials that are non-hazardous to members of the public in case of fire. It is now understood that smoke and poisonous fumes can be a greater risk to lives than that of fire alone. The biggest issue is the full understanding of what is a true low smoke free halogen cable (LSHF, LSZH, LSOH).To be assured you are buying a cable that will offer security during fire, it must pass 3 tests pertaining to halogen content, low smoke density and flame propagation. Lapp’s range of low smoke halogen free products are stringently tested to CCC and ISO standards to ensure peace of mind when installing these cables where human life or valuable property are exposed to a high risk of fire hazards.
1.Application:
·Modern life safety systems, encompassing both fire detection and alarm system·Building management systems·Emergency lighting·Public address·Standby power supplies·Computer installations·Lifts and elevatorsTheir prolonged operation in a fire situation provides vital additional time to accomplish the evacuation of personnel, to contain and minimize the damage to equipment, plant and buildings, and to mount an effective fire fighting operation. 2.Cable structure: Conductor : Class 2 annealed stranded plain copperInsulation :XLPEJacket: LSHF shtath
3.Technical Data Sheet
corss section(mm2) | insulation thickness(mm) | sheath thickness(mm) | approx.overall diameter(mm) | approx.weight of cable(kg/km) | resistance of conductor(Ω/km) | testing voltage(kv/5min) | current rating(a) |
1*10 | 0.7 | 1.4 | 8 | 145 | 1.83 | 3.5 | 71 |
1*16 | 0.7 | 1.4 | 9 | 207 | 1.15 | 3.5 | 92 |
1*50 | 1.0 | 1.4 | 13 | 408 | 0.524 | 3.5 | 150 |
1*70 | 1.1 | 1.5 | 14 | 753 | 0.268 | 3.5 | 230 |
3*10 | 0.7 | 1.8 | 15 | 464 | 1.83 | 3.5 | 65 |
3*16 | 0.7 | 1.8 | 17 | 666 | 1.15 | 3.5 | 84 |
3*50 | 1.0 | 1.8 | 27 | 1625 | 0.387 | 3.5 | 170 |
3*70 | 1.1 | 1.9 | 30 | 2235 | 0.268 | 3.5 | 215 |
4*10 | 0.7 | 1.8 | 16 | 570 | 1.83 | 3.5 | 65 |
4*16 | 0.7 | 1.8 | 19 | 821 | 1.15 | 3.5 | 84 |
4*50 | 1.0 | 1.9 | 28 | 2146 | 0.387 | 3.5 | 170 |
4*70 | 1.1 | 2.0 | 32 | 2954 | 0.268 | 3.5 | 215 |
4*16+1*10 | 0.7 | 1.5 | 22 | 965 | 1.15/1.83 | 3.5 | 83 |
4*25+1*16 | 0.9 | 2.0 | 26 | 1456 | 0.727/1.15 | 3.5 | 105 |
4*70+1*35 | 1.1 | 2.0 | 39 | 3565 | 0.268/0.524 | 3.5 | 200 |
this is part of specification, more specification contace me!!!